iMX6 TinyRex Memory Calibration
Revision as of 21:07, 14 March 2021 by Voipac (talk | contribs) (Created page with "Category:iMX6 TinyRex Development kit Category:iMX6 TinyRex Peripherals <!-- --> <div style="float:right">__TOC__</div> ''''Caution:'''' This procedure is intended fo...")
'Caution:' This procedure is intended for manufacturing use only and should be never applied for shipped iMX6 TinyRex boards.
Description
Memory calibration procedure consists from following steps:
- Short BOOT_MODE jumper on i.MX6 TinyRex Base board
- Connect USB_OTG port to host PC utilizing microUSB-USB cable
- Power on i.MX6 TinyRex Development kit
- Execute DDR Stress Tester at host PC using command line
- Configure DDR Stress Tester and calibrate memory
- Remove BOOT_MODE jumper
- Power off i.MX6 TinyRex Development kit
Requirements
- micro USB cable
- 5V 2A Power supply
- i.MX6 TinyRex Module and Base board
- PC controlling the test
- DDR Stress Tester 1.0.3 application
- DDR Stress Tester 2.52 application