iMX8M Industrial Power Consumption
Jump to navigation
Jump to search
This page contains power consumption measurement for the iMX8M Industrial Development kit in all the standard configurations.
Test setup and measuring equipment
- power supply: BK PRECISION 1688B
- 2x digital multimeter: FLUKE 115 TRUE RMS
Power consumption results
iMX8M Industrial Development Kit Basic
Test condition | Input voltage Vin [V] |
Measured current I [A] |
Power usage P [W] |
---|---|---|---|
Uboot only | 5.183 | 0.463 | 2.400 |
Booting-up process (maximum) | 5.177 | 0.72 | 3.727 |
Linux at idle | 5.184 | 0.423 | 2.193 |
Linux + ETH | 5.182 | 0.49 | 2.539 |
Linux + ETH + HDMI | 5.179 | 0.566 | 2.931 |
Linux + ETH + HDMI + Stresstest | 5.173 | 0.791 | 4.092 |