On this page environmental stress testing results of iMX6 Rex Development kit are displayed. Detailed instructions about how to setup iMX6 Rex Development kit are also shown. The original article can be accessed on the iMX6Rex.com website.

Hardware configuration

For our testing we used following hardware configuration (you can use anything you have, just be aware of temperature range of the components fitted on your board):

  • 3x iMX6 Rex Development kit in modified Pro configuration
    • 1GHz iMX6 Quad CPU - extended temperature range (-20°C to +105°C)
    • 4x 4Gb DDR3 Memory chips - commercial temperature range (0°C to +95°C)
    • 1GBps Ethernet PHY Tranciever KSZ9021RN - commercial temperature range (0°C ~ +70°C)
  • 1x iMX6 Rex Development kit in alternative Pro configuration
    • 1GHz iMX6 Quad CPU - extended temperature range (-20°C to 105°C)
    • 4x 2Gb DDR3 Memory chips - commercial temperature range (0°C to +95°C)
    • 1GBps Ethernet PHY Tranciever KSZ9021RN - commercial temperature range (0°C to +70°C)

Note: An industrial iMX6 Rex heatsink was used. With a bigger heatsink you can achieve higher temperature.

The setup in environmental chamber: 800px

Test description