This page contains power consumption measurement for the iMX8M Industrial Development kit in all the standard configurations.
Test setup and measuring equipment
- power supply: BK PRECISION 1688B
- 2x digital multimeter: FLUKE 115 TRUE RMS
Power consumption results
iMX8M Industrial Development Kit Basic
rowspan="2" | Test condition | Vin [V] | I [A] | P [W] |
---|---|---|---|---|
Uboot only | 5.183 | 0.463 | 2.400 | |
Booting-up process (maximum) | 5.177 | 0.72 | 3.727 | |
Linux at idle | 5.184 | 0.423 | 2.193 | |
Linux + ETH | 5.182 | 0.49 | 2.539 | |
Linux + ETH + HDMI | 5.179 | 0.566 | 2.931 | |
Linux + ETH + HDMI + Stresstest | 5.173 | 0.791 | 4.092 |