Difference between revisions of "iMX8M Industrial EMC testing"

From Voipac Wiki
Jump to navigation Jump to search
Line 70: Line 70:
 
==== Radiated Emissions ====
 
==== Radiated Emissions ====
 
The measurement starts with peak detection by scanning the whole frequency spectrum. This initial detection is plotted with the green curve at MES_EN_55032-B_pre_PK. Afterwards the five highest peaks were pointed and measured more thoroughly by quasi-peak method. These real measured values of the radiation are displayed with the red crosses at MES_EN_55032-B_fin_QP. The graph shows the setup passed the strict residential 55032-B limit represented by the red highlighted line.<br />
 
The measurement starts with peak detection by scanning the whole frequency spectrum. This initial detection is plotted with the green curve at MES_EN_55032-B_pre_PK. Afterwards the five highest peaks were pointed and measured more thoroughly by quasi-peak method. These real measured values of the radiation are displayed with the red crosses at MES_EN_55032-B_fin_QP. The graph shows the setup passed the strict residential 55032-B limit represented by the red highlighted line.<br />
 +
 +
The frequency spectrum around 30 MHz was heavily influenced by the power adapter used during this test. Further examination proved that input power sources emitting less noise lead to overall more superior results.<br />
  
 
These results prove that iMX8M Industrial Development Kit, even under heavy load, meets the stricter limits even if no enclosure is used.
 
These results prove that iMX8M Industrial Development Kit, even under heavy load, meets the stricter limits even if no enclosure is used.
Line 104: Line 106:
 
==== Radiated Emissions ====
 
==== Radiated Emissions ====
 
The measurement starts with peak detection by scanning the whole frequency spectrum. This initial detection is plotted with the green curve at MES_EN_55032-B_pre_PK. Afterwards the five highest peaks were pointed and measured more thoroughly by quasi-peak method. These real measured values of the radiation are displayed with the red crosses at MES_EN_55032-B_fin_QP. The graph shows the setup passed the strict residential 55032-B limit represented by the red highlighted line.<br />
 
The measurement starts with peak detection by scanning the whole frequency spectrum. This initial detection is plotted with the green curve at MES_EN_55032-B_pre_PK. Afterwards the five highest peaks were pointed and measured more thoroughly by quasi-peak method. These real measured values of the radiation are displayed with the red crosses at MES_EN_55032-B_fin_QP. The graph shows the setup passed the strict residential 55032-B limit represented by the red highlighted line.<br />
 +
 +
The frequency spectrum around 30 MHz was heavily influenced by the power adapter used during this test. Further examination proved that input power sources emitting less noise lead to overall more superior results.<br />
  
 
These results prove that iMX8M Industrial Development Kit, even under heavy load, meets the stricter limits even if no enclosure is used.
 
These results prove that iMX8M Industrial Development Kit, even under heavy load, meets the stricter limits even if no enclosure is used.

Revision as of 14:50, 22 July 2022

Electromagnetic compatibility results for iMX8M Industrial Development Kit are presented on this page. Test setup and scripts are described in details.

These measurements were performed with setups using the actual hardware and software configurations of the web shop development kits.

Connected cables/devices

  • Power source: +5V 40W power supply used for input voltage
  • Storage device: eMMC Flash memory soldered on module used for booting, filesystem operation and script storage
  • Ethernet: 1m long CAT Ethernet loopback cable connected. Forced to 100Mbps and used for ping test
  • DisplayPort (M) interface used with LCD monitor connected: Full-HD output video stream generated and sent to LCD monitor via 2m long DisplayPort cable, with ferrite bead added. The output signal forced to be continuously generated, contributing to EMC spectrum, even though monitor was plugged into mains but not turned on, and laid flat on the floor to minimise its affect on results. Used LCD monitor: 29" LG UltraWide 29WP60G-B 2560x1080 px
  • LCD Display: Newhaven LVDS Capacitive Display Set with 1024x600 resolution. LCD PN: NHD-10.1-1024600MB-LSXV-CTP
  • 2x USB 3.0: SanDisk Ultra Flair 16GB USB 3.2 Gen 1, each connected through a 1m long USB 3.2 Gen 1 extension cable (Molex PN: 0687890035). Both used during read/write test
  • USB-C: Kingston DataTraveler 80 32GB USB 3.2 Gen 1, connected through USB-C extension cable (Cable PN: FCR72003)
  • Camera: Digilent MIPI-CSI Camera Set plugged to the baseboard, recognised by the kernel, not actively used during testing. Ferrite bead added close to the camera module (PN: SRP33.5x6.5x10)
  • CAN: CANbus Module inserted, but not actively used. CAN cable not connected
  • WiFi and Bluetooth: Soldered directly on COM, not actively used. Depending on the temperature range, the default SPB228-D-3 or alternative CM-276NF module populated. Two antennas plugged and connected
  • Console cable: Micro USB extension cable used only to setup the development kit, not plugged in during the measurements
  • SD card: SD card (SanDisk) plugged in and used during read/write test
  • Microphone: Microphone connected but not actively used
  • Headphones: Headphones connected but not actively used
  • Speakers: Line Out connected but not actively used


800px

Testing conditions and results

All the results were measured in compliance with the emission limits for FCC Class B (EMC standard EN 55032B). Class B devices are suitable for both residential and industrial applications as the norm standards use more restrictive limits.

iMX8M Industrial Development Kit Max - Module and peripherals under heavy load – PASSED

Test description:

  • development kit configuration:
    • iMX8M Industrial Module Max in Industrial temperature range
    • iMX8M Development Baseboard in Extended temperature range
  • CPU heavy testing threads using stressapptest
  • DDR4 memory heavy testing threads using stressapptest
  • Ethernet loopback cable used for network testing
  • running heavy read/write testing for USB devices and SD card
  • cables and devices plugged in but not actively used:
  • peripherals heavy testing script used

Radiated Emissions

Both vertical and horizontal polarisation results in range from 30MHz to 1GHz were measured and captured during this EMC test session. Radiated emissions were measured and displayed as peak values. This relation is represented as a green curve in the measurements. The red highlighted line displays Class B limits. The Bilog antenna CBL6112A operating in range from 30MHz to 2GHz was used.

iMX8M Industrial EMC Modul6 Only Test.jpg

Conducted Emissions

iMX8M Industrial EMC Modul6 Only Test Conductive.jpg

iMX8M Industrial Development Kit Basic - Testing peripherals and external LCD display – PASSED

Test description:

800px

Radiated Emissions

The measurement starts with peak detection by scanning the whole frequency spectrum. This initial detection is plotted with the green curve at MES_EN_55032-B_pre_PK. Afterwards the five highest peaks were pointed and measured more thoroughly by quasi-peak method. These real measured values of the radiation are displayed with the red crosses at MES_EN_55032-B_fin_QP. The graph shows the setup passed the strict residential 55032-B limit represented by the red highlighted line.

The frequency spectrum around 30 MHz was heavily influenced by the power adapter used during this test. Further examination proved that input power sources emitting less noise lead to overall more superior results.

These results prove that iMX8M Industrial Development Kit, even under heavy load, meets the stricter limits even if no enclosure is used.

Vertical + Horizontal polarisation in lower band 30MHz - 1GHz

Antenna used: Bilog CBL6112A 30 MHz to 2GHz

iMX8M Industrial NH LVDS LCD USB Audio Camera Module 2.jpg

Vertical + Horizontal polarisation in higher band 1GHz - 6GHz

Antenna used: Double-Ridged Waveguide Horn Antenna 1GHz to 18GHz

File:iMX8M Industrial Basic-Radiated emissions 1-6GHz.png

Conducted Emissions

iMX8M Industrial NH LVDS Module 2 Conductive.jpg

iMX8M Industrial Development Kit Max - Testing module and DisplayPort output - PASSED

Test description:

  • development kit configuration:
    • iMX8M Industrial Module Max in Industrial temperature range
    • iMX8M Development Baseboard in Extended temperature range
  • CPU heavy testing threads using stressapptest
  • DDR4 memory heavy testing threads using stressapptest
  • Ethernet loopback cable used for network testing
  • DisplayPort output tested in Full-HD 2560x1080 resolution
  • cables and devices plugged in but not actively used:
  • module heavy testing script used

iMX8M Industrial DP EMC Table.jpg

Radiated Emissions

The measurement starts with peak detection by scanning the whole frequency spectrum. This initial detection is plotted with the green curve at MES_EN_55032-B_pre_PK. Afterwards the five highest peaks were pointed and measured more thoroughly by quasi-peak method. These real measured values of the radiation are displayed with the red crosses at MES_EN_55032-B_fin_QP. The graph shows the setup passed the strict residential 55032-B limit represented by the red highlighted line.

The frequency spectrum around 30 MHz was heavily influenced by the power adapter used during this test. Further examination proved that input power sources emitting less noise lead to overall more superior results.

These results prove that iMX8M Industrial Development Kit, even under heavy load, meets the stricter limits even if no enclosure is used.

Vertical + Horizontal polarisation in lower band 30MHz - 1GHz

Antenna used: Bilog CBL6112A 30 MHz to 2GHz

iMX8M Industrial EMC Modul6 DisplayPort Audio USB CAN.jpg

Vertical + Horizontal polarisation in higher band 1GHz - 6GHz

Antenna used: Double-Ridged Waveguide Horn Antenna 1GHz to 18GHz

File:iMX8M Industrial Max-Radiated emissions 1-6GHz.png

Preparing the test

Boot device and software

These measurements were performed with boards using the actual hardware and software configuration of the web shop development kits.

eMMC Flash memory was selected as a booting device for all the measurements. U-Boot settings were not adjusted as the default configuration was used.

Running the script

Plug the development kit into mains and connect it to the controlling PC via console. Before the first time usage of the script, permissions need to be granted by the following command:

chmod +x imx8m-voipac-peripheral-test.sh


Testing scripts command consists of the following arguments:

  • the first parameter - configuration of tested development kit (Max, Pro or Basic)
  • the second parameter - USB drive 1 location
  • the third parameter - USB drive 2 location
  • the fourth parameter - SD card location


Several commands used during EMC testing are shown below:

  • iMX8M Industrial Development Kit Max:
./imx8m-voipac-peripheral-test.sh -max sda1 sdb1 mmcblk1p1 | tee -i imx8m-emc-testing.log
  • iMX8M Industrial Development Kit Pro:
./imx8m-voipac-peripheral-test.sh -pro sda1 sdb1 mmcblk1p1 | tee -i imx8m-emc-testing.log
  • iMX8M Industrial Development Kit Basic:
./imx8m-voipac-peripheral-test.sh -basic sda1 sdb1 mmcblk1p1 | tee -i imx8m-emc-testing.log

Testing scripts

Peripherals heavy testing script

This code was used during the measurements, focusing on peripherals influence on the emissions. The complete script can also be found in the downloads section.

#!/bin/sh
 
# iMX8M Industrial Development Kit peripheral test
  
mountDevice() {
  mkdir -p "/media/$2"
  mount /dev/$1 /media/$2
  cat /proc/mounts | grep -F "/dev/$1 /media/$2"
  if [ "$?" -eq "0" ]; then
    echo "$2 mounted"
  else
    echo "$2 not mounted"; exit 2
  fi
}
 
# prepare files
cd ~/
mkdir -p imx8m-industrial-testing/
cd imx8m-industrial-testing/
   
touch imx8m-industrial-testing.log
touch cpu-temp.log
 
basic=0
pro=0
max=0
case $1 in
  -basic)  basic=1 ;;
  -pro)  pro=1 ;;
  -max)  max=1 ;;
  *)
esac
  
# mount devices
mountDevice $2 usb0
mountDevice $3 usb1
mountDevice $4 mmc0
 
updateLogFiles() {
  # obtain board ID from IP address - be sure addresses are allocated based on MAC
  boardID=$(/sbin/ip -o -4 addr list eth0 | awk '{print $4}' | cut -d/ -f1 | cut -d'.' -f4 | cut -d'2' -f2);
  # be sure time server is running on DHCP server
  currentTime=`date +%Y-%m-%d.%H:%M`
   
  mv imx8m-industrial-testing.log imx8m-industrial-$boardID-testing.log.$currentTime
  mv cpu-temp.log imx8m-industrial-$boardID-cpu-temp.log.$currentTime
}
 
finish_test_now() {
  echo "$(date +\%Y/\%m/\%d-\%T)($(date +\%Z)) Ctrl+C Detected: End of the test"
  precced=0;
  #kill -INT $vid_pid $str_pid $log_pid;
  sleep 3;
  test_status=`cat imx8m-industrial-testing.log | grep -i "error" | grep -v -e "0 errors" -e "no corrected errors"`
  if [ -z "$test_status" ]
  then
    echo "*********TEST PASS*********"
  else
    echo "*********TEST FAIL*********"
    echo "List of detected errors:"
    cat imx8m-industrial-testing.log | grep -i "error" | grep -v -e "0 errors" -e "no corrected errors" -e "List of detected errors:"
  fi
  updateLogFiles
  exit;
}
  
# kill all processes if Ctrl+C is detected
trap finish_test_now 2
 
# play a video stream from HDMI input - testing also HDMI output
gst-launch-1.0 -q imxv4l2src ! autovideosink &
 
# stressapptest - one thread CPU, one thread memory, sata thread (if possible)
if [ "${basic}" -eq "1" ]; then
  stress-ng --cpu 2 --vm 4 &
  str_pid=$!
fi
if [ "${pro}" -eq "1" ]; then
  stress-ng --cpu 4 --vm 4 &
  str_pid=$!
fi
if [ "${max}" -eq "1" ]; then
  stress-ng --cpu 4 --vm 4 &
  str_pid=$!
fi
echo "$(date +\%Y/\%m/\%d-\%T)($(date +\%Z)) Starting stressapptest with PID: " $str_pid
  
proceed=1
# create test files
file1_path=`mktemp`
file2_path=`mktemp`
file1=`basename $file1_path`
file2=`basename $file2_path`

dd if=/dev/urandom of=$file1_path bs=1024 count=10000
dd if=/dev/urandom of=$file2_path bs=1024 count=10000
 
cp1_from="/media/mmc0/"
cp1_to="/media/usb0/"
 
cp2_from="/media/usb0/"
cp2_to="/media/usb1/"
 
#copy files in case they are missing
cp $file1_path $cp1_from
cp $file1_path $cp1_to
cp $file2_path $cp2_from
cp $file2_path $cp2_to
  
while [ $proceed -eq 1 ]
do
  # before running script check if the ip address exist 
  ping -q -c1 192.168.0.2 >> imx8m-industrial-testing.log
  if [ $? -ne 0 ]
  then
    echo "$(date +\%Y/\%m/\%d-\%T)($(date +\%Z)) ERROR: Ping failed"
  else
    echo "$(date +\%Y/\%m/\%d-\%T)($(date +\%Z)) Ping OK"
  fi
  
  cp1_done=`ps | grep $cp1_pid | grep cp`
  if [ -z "$cp1_done" ]; then # copy finished
    if cmp -s $cp1_from$file1 $cp1_to$file1; then
      echo "$(date +\%Y/\%m/\%d-\%T)($(date +\%Z)) PASS: Copying file from $cp1_from to $cp1_to successful"
    else
      echo "$(date +\%Y/\%m/\%d-\%T)($(date +\%Z)) ERROR: Difference between files on $cp1_from and $cp1_to detected"
    fi
    cp1_temp=$cp1_from # swap destinations
    cp1_from=$cp1_to
    cp1_to=$cp1_temp
      
    rm $cp1_to$file1 # remove destination file
      
    cp $cp1_from$file1 $cp1_to$file1 &
    cp1_pid=$!
    echo "$(date +\%Y/\%m/\%d-\%T)($(date +\%Z)) Started copying file from $cp1_from to $cp1_to"
  fi
    
  cp2_done=`ps | grep $cp2_pid | grep cp`
  if [ -z "$cp2_done" ]; then # copy finished
    if cmp -s $cp2_from$file2 $cp2_to$file2; then
      echo "$(date +\%Y/\%m/\%d-\%T)($(date +\%Z)) PASS: Copying file from $cp2_from to $cp2_to successful"
    else
      echo "$(date +\%Y/\%m/\%d-\%T)($(date +\%Z)) ERROR: Difference between files on $cp2_from and $cp2_to detected"
    fi
    cp2_temp=$cp2_from # swap destinations
    cp2_from=$cp2_to
    cp2_to=$cp2_temp
      
    rm $cp2_to$file2 # remove destination file
      
    cp $cp2_from$file2 $cp2_to$file2 &
    cp2_pid=$!
    echo "$(date +\%Y/\%m/\%d-\%T)($(date +\%Z)) Started copying file from $cp2_from to $cp2_to"
  fi
  
done

Module heavy testing script

This script was utilised for testing procedure where the measurement was primarily focused on the module emissions. To use this script, plug the development kit into mains, connect it to controlling PC via console and copy the code below:

for d in $(seq 1 1 999)
do
	uptime
	echo "Test $a Test $b Test $c  $d times"
	echo "Start stress-ng --iomix 1 -t 10 -v"
	stress-ng --iomix 1 -t 10 -v
	echo "End"
	echo "Start Thermal zone information"
	stress-ng --matrix 0 --tz -t 10 --log-brief -t 10
	echo "End"
	ping -q -c1 192.168.0.2 >> imx8m-industrial-testing.log
	  if [ $? -ne 0 ]
	  then
		echo "$(date +\%Y/\%m/\%d-\%T)($(date +\%Z)) ERROR: Ping failed"
	  fi
	echo "End"
done