== Testing Results == | == Testing Results == | ||
The picture below shows the temperature profile during the whole testing process:<br /> | The picture below shows the temperature profile during the whole testing process:<br /> | ||
− | [[image:iMX6_Rex_Development_kit-Env_chamber-Temperature_profile. | + | [[image:iMX6_Rex_Development_kit-Env_chamber-Temperature_profile.png|680px]] |
=== Switch ON/OFF test – PASS === | === Switch ON/OFF test – PASS === | ||
Line 48: | Line 48: | ||
=== Running the boards at -25°C – PASS === | === Running the boards at -25°C – PASS === | ||
Test description: Ambient temperature was set to -25°C and the CPU and Memory stress tests were running. | Test description: Ambient temperature was set to -25°C and the CPU and Memory stress tests were running. | ||
− | [[image:iMX6_Rex_Development_kit-Env_chamber-Logs_-25°C. | + | [[image:iMX6_Rex_Development_kit-Env_chamber-Logs_-25°C.png|800px]] |
=== Running the boards at +70°C – PASS === | === Running the boards at +70°C – PASS === | ||
Test description: Ambient temperature was set to +70°C and the CPU and Memory stress tests were running. | Test description: Ambient temperature was set to +70°C and the CPU and Memory stress tests were running. | ||
− | [[image:iMX6_Rex_Development_kit-Env_chamber-Logs_+70°C. | + | [[image:iMX6_Rex_Development_kit-Env_chamber-Logs_+70°C.png|800px]] |
=== Fast change of the temperature (from -25°C to +70°C) – PASS === | === Fast change of the temperature (from -25°C to +70°C) – PASS === | ||
Line 88: | Line 88: | ||
=== Setup the SSH connections === | === Setup the SSH connections === | ||
During the testing a simple local Ethernet network utilising a LAN switch and a control laptop was created. Two SSH sessions per board were opened (8 sessions in total). The first session was used for CPU and memory stress test. In the window below the current CPU temperature was printed out. The other three boards used the same format: | During the testing a simple local Ethernet network utilising a LAN switch and a control laptop was created. Two SSH sessions per board were opened (8 sessions in total). The first session was used for CPU and memory stress test. In the window below the current CPU temperature was printed out. The other three boards used the same format: | ||
− | [[image:iMX6_Rex_Development_kit-Env_chamber-Logs_setup. | + | [[image:iMX6_Rex_Development_kit-Env_chamber-Logs_setup.png|800px]] |
=== Set up the date === | === Set up the date === |
Revision as of 17:11, 31 August 2021
On this page environmental stress testing results of iMX6 Rex Development kit are displayed. Detailed instructions how to setup iMX6 Rex Development kit are also shown.
Hardware configuration
Following hardware configurations were used for the testing:
- 3x iMX6 Rex Development kit in Pro configuration
- i.MX6 Quad 1.0 GHz CPU - extended temperature range (-20°C to +105°C)
- 2GB DDR3 Memory (4x 4Gb DDR3 Memory chips) - commercial temperature range (0°C to +95°C)
- 1GBps Ethernet PHY Tranciever KSZ9021RN - commercial temperature range (0°C to +70°C)
- 1x iMX6 Rex Development kit in modified Pro configuration
- i.MX6 Quad 1.0 GHz CPU - extended temperature range (-20°C to +105°C)
- 1GB DDR3 Memory (4x 2Gb DDR3 Memory chips) - commercial temperature range (0°C to +95°C)
- 1GBps Ethernet PHY Tranciever KSZ9021RN - commercial temperature range (0°C to +70°C)
Note: During the chamber testing a heatsink covering the whole module was used. With a bigger heatsink, maximum operating temperature can be further extended.
The setup in environmental chamber:
800px
Test description
The main purpose of this test is to check memory stability of iMX6 Rex Module. During the test these threads will be running:
- 4 threads of extensive memory stress test
- 4 threads of CPU stress test
This is the main command used for the test:
stressapptest -s 600000 -M 768 -m 4 -C 4 -W --printsec 600 -l /home/ubuntu/testing-env-chamber/stressapptest.log
Detailed description about how to setup and run the whole test can be found in section How to prepare the test. It describes all the scripts and explains log files.
Testing Results
The picture below shows the temperature profile during the whole testing process:
680px
Switch ON/OFF test – PASS
Test description: Boards were switched OFF, left OFF for 10 minutes and then switched ON. These tests were done several times for temperatures between -30°C to -35°C and for a temperature +70°C. All the boards booted up successfully.
396px | 396px |
Running the boards at -25°C – PASS
Test description: Ambient temperature was set to -25°C and the CPU and Memory stress tests were running. 800px
Running the boards at +70°C – PASS
Test description: Ambient temperature was set to +70°C and the CPU and Memory stress tests were running. 800px
Fast change of the temperature (from -25°C to +70°C) – PASS
Test description: Ambient temperature was rapidly changed from -25°C to +70°C. The CPU and Memory stress tests were running.
Preparing the test
SD card setup
Linux 4.1 kernel was used for this test. Modified Xubuntu filesystem can be accessed from here. To create a new SD card, these instructions can be followed.
Create the log files
mkdir /home/ubuntu/testing-env-chamber cd /home/ubuntu/testing-env-chamber touch cpu-temp.log touch stressapptest.log
Setup the cron
To be able to check the CPU temperature every minute a new cron job was setup. For Ubuntu file systems postfix package installation is required:
sudo apt-get install postfix
To setup a cron tab, the file containing all cron jobs needs to be altered. Before running the crontab for the first time, selecting a text editor is required:
sudo crontab -e
Paste the following line to the end of the cron list file. The output time format will be set the same as for stressapptest. Cron job performs a current CPU temperature readout and the data are saved in the log file:
* * * * * { echo -n $(date +\%Y/\%m/\%d-\%T); echo -n "("; echo -n $(date +\%Z); echo -n ") "; cat /sys/devices/virtual/thermal/thermal_zone0/temp; } >> /home/ubuntu/testing-env-chamber/cpu-temp.log
Note: The percent sign '%' has a special purpose in the cron file. As this sign is needed to write the date formats, the backslash is required to be placed before the percent sign: '\%'.
Setup the SSH connections
During the testing a simple local Ethernet network utilising a LAN switch and a control laptop was created. Two SSH sessions per board were opened (8 sessions in total). The first session was used for CPU and memory stress test. In the window below the current CPU temperature was printed out. The other three boards used the same format: 800px
Set up the date
As the RTC clock was not used during the test, the current time is set after boards boot up. A time zone is updated first:
ln -sf /usr/share/zoneinfo/Europe/Bratislava /etc/localtime
The actual time is changed afterwards. Sequence of digits in the following order was used: month day hour minute year. The command below sets this time and date: 04-July-2014 08:26
date 070408262014
Setup the CPU temperature printout
Before the CPU and memory stress tests start, the old logs were backed up:
cd /home/ubuntu/testing-env-chamber mv cpu-temp.log cpu-temp-testing1.log mv stressapptest.log stressapptest-testing1.log touch cpu-temp.log touch stressapptest.log
Tail command is used to read the temperature. It displays the last part of files (the cron job is writing to this log file):
tail -F cpu-temp.log
Start the stress test
stressapptest -s 600000 -M 768 -m 4 -C 4 -W --printsec 600 -l /home/ubuntu/testing-env-chamber/stressapptest.log
To make sure test is running smoothly, potential errors can be found in the log file (instead of rolling the stress test printout):
grep -i "error" stressapptest.log
The original article can be accessed on the iMX6Rex.com website.