Difference between revisions of "iMX6 Rex Environmental chamber testing"
Line 14: | Line 14: | ||
<br /> | <br /> | ||
* 1x iMX6 Rex Development kit in alternative Pro configuration | * 1x iMX6 Rex Development kit in alternative Pro configuration | ||
− | ** 1GHz iMX6 Quad CPU - extended temperature range (-20°C to 105°C) | + | ** 1GHz iMX6 Quad CPU - extended temperature range (-20°C to +105°C) |
** 4x 2Gb DDR3 Memory chips - commercial temperature range (0°C to +95°C) | ** 4x 2Gb DDR3 Memory chips - commercial temperature range (0°C to +95°C) | ||
** 1GBps Ethernet PHY Tranciever KSZ9021RN - commercial temperature range (0°C to +70°C) | ** 1GBps Ethernet PHY Tranciever KSZ9021RN - commercial temperature range (0°C to +70°C) |
Revision as of 13:00, 25 March 2021
On this page environmental stress testing results of iMX6 Rex Development kit are displayed. Detailed instructions about how to setup iMX6 Rex Development kit are also shown.
Hardware configuration
For the testing following hardware configurations were used:
- 3x iMX6 Rex Development kit in modified Pro configuration
- 1GHz iMX6 Quad CPU - extended temperature range (-20°C to +105°C)
- 4x 4Gb DDR3 Memory chips - commercial temperature range (0°C to +95°C)
- 1GBps Ethernet PHY Tranciever KSZ9021RN - commercial temperature range (0°C ~ +70°C)
- 1x iMX6 Rex Development kit in alternative Pro configuration
- 1GHz iMX6 Quad CPU - extended temperature range (-20°C to +105°C)
- 4x 2Gb DDR3 Memory chips - commercial temperature range (0°C to +95°C)
- 1GBps Ethernet PHY Tranciever KSZ9021RN - commercial temperature range (0°C to +70°C)
Note: An industrial iMX6 Rex heatsink was used. With a bigger heatsink you can achieve higher temperature.
The setup in environmental chamber:
800px
Test description
The main purpose of this test is to check memory stability of iMX6 Rex Module. During the test you will be running:
- 4 threads of extensive memory stress test
- 4 threads of CPU stress test
This is the main command used for the test:
# stressapptest -s 600000 -M 768 -m 4 -C 4 -W --printsec 600 -l /home/ubuntu/testing-env-chamber/stressapptest.log
Detailed description about how to setup and run the whole test can be found in section How to prepare the test. It describes all the scripts and explains log files.
Testing Results
Here are the results of the testing. In the picture below you can see the temperature profile which was set during the testing:
800px
Switch ON/OFF test - PASS
Test description: Boards were switched OFF , left OFF for 10 minutes and then switched ON. These tests were done several times for temperatures between -30°C to -35°C and for a temperature +70°C. All the boards booted up successfully.
400px | 400px |
Running the boards at -25°C - PASS
Test description: Ambient temperature was set to -25°C and the CPU and Memory stress tests were running. 800px
Running the boards at +70°C - PASS
Test description: Ambient temperature was set to +70°C and the CPU and Memory stress tests were running. 800px
Fast change of the temperature (from -25°C to +70 °C) - PASS
Test description: Ambient temperature was rapidly changed from -25°C to +70 °C. The CPU and Memory stress tests were running.
Preparing the test
SD card setup
For this test we used this kernel and Xubuntu filesystem. To create a new SD card, these instructions can be followed.
Create the log files
# mkdir /home/ubuntu/testing-env-chamber # cd /home/ubuntu/testing-env-chamber # touch cpu-temp.log # touch stressapptest.log
Setup the cron
To be able to check the CPU temperature every minute a new cron job is setup. postfix package install is required in this case (for Ubuntu file systems):
# sudo apt-get install postfix
To setup a cron tab, the file containing all cron jobs needs to be altered. Before running the crontab for the first time selecting a text editoris required:
# sudo crontab -e
Paste following line to the end of this file. The output time format will be the as for stressapptest, the current CPU temperature will be gathered and saved in the log file.
Note: The percent char '%' has a special purpose in the cron file. When using it in the date command backslash usage before the percent '\%' is needed:
* * * * * { echo -n $(date +\%Y/\%m/\%d-\%T); echo -n "("; echo -n $(date +\%Z); echo -n ") "; cat /sys/devices/virtual/thermal/thermal_zone0/temp; } >> /home/ubuntu/testing-env-chamber/cpu-temp.log
Setup the SSH connections
We created a simple Eth net with switch and control laptop. We opened 2 SSH session per board (8 session in total). In the first session we started CPU and memory stress test. In the window below we printed out the current CPU temperature. For the next three board we did exactly the same.
The original article can be accessed on the iMX6Rex.com website.